Description
- 4000 counts, 42 segments analog bar graph
- Frequency measurement by clamping and using test lead
- Data hold
- Continuity check buzzer
- Auto power off (30 min.)
- Low battery power indication
Specifications
Function | Measuring range | Best accuracy | Resistance |
---|---|---|---|
ACA | 40/400A | (1.9%+5) | 0.01A |
ACV | 400/600V | (1.5%+5) | 0.1V |
DCV | 400/600V | (1%+2) | 0.1V |
Resistance | 400 | (1%+2) | 0.1 |
Frequency (A) | 204k/10kHz | (0.1%+1) | 1Hz |
Frequency (V) | 4k/40k/400k/1MHz | (0.1%+1) | 0.001kHz |
Continuity | Buzzer sounds at less than approx. 40 Open voltage: approx. 1.5V |
Sampling rate | 2 times/sec., 20 times/sec. for bar graph |
Bandwidth | ACA 50/60Hz: (1.9%+5 60-500Hz: (2.5%+5 ACV 50-500Hz: (1.5%+5) |
Display | 4000 |
Clamp diameter/Conductor size | 25mm/1034mm |
Battery | R032 |
Battery life | Approx. 150 hrs. (Zinc-carbon battery) |
Size/Mass | H193W50D28mm/Approx. 230g |
Safety standards | IEC61010 CAT.300V CAT.600V |
Reviews